Product
Category |
| |
|
|
|
|
Sign Up Now |
|
Exclusive Offers & Discounts |
Click here to Register: |
 |
|
|
|
|
| C 200 Calorimeter System |
The IKA C 200 is a space-saving and low cost combustion bomb calorimeter system for determining gross calorific values of both liquid and solid samples.
The C 200 system consists of the following components:
• Measuring cell C 200
• Decomposition vessel C 5010
• Oxygen filling station C 248
• Consumables for calibrations and installation
Features and Benefits:
• Suitable for teaching and training laboratories (i.e. technical schools, universities) as well as for industrial laboratories where reduced sample analyses is required.
• Four different working modes: isoperibolic, dynamic, manual, and time-controlled
• Manual handling for water and oxygen filling.
• Clear and easy to operate user-interface
• Validation according to DIN 51900, ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711.
• 1+1 year warranty after registering at www.ika.com/register
• 24 hour technical support hotline
• Manufactured in the USA
Read More
The modes have different measuring times:
isoperibol, measurement time: approx. 22 min
dynamic, measurement time: approx. 7 min
Cooling water supply via thermostat e.g. IKA KV 600 (Ident. No. 3410501) or firmly installed water connection (C 25 pressure regulating valve (Ident. No. 3197200) recommended)
Interface connections for each of the following: scale, printer, monitor and sample rack C 5020 (Ident. No. 7145000)
User-friendly software C 5040 CalWin (Ident. No. 3045000) is available for controlling the calorimeter and administration of measuring data
Up to eight oxygen bomb calorimeters can be controlled by a single PC, using a multi-serial plug in card PCI 8.2 (accessory)
|
|
| |
| C 2000 basic version 1 Calorimeter |
The IKA C 2000 basic bomb calorimeter is a combustion calorimeter for determining gross calorific values of liquid and solid samples. A high level of automation with extremely simple handling characterizes this instrument. In addition to the isoperibolic measurement procedure (static jacket), a dynamic (reduced-time) working method is also available. To provide the calorimeter with cooling water, it needs to be connected to the IKA thermostat KV 600, which is included in this package..
The C 2000 system consists of the following components:
• Measuring cell C 2000
• Decomposition vessel C 5010
• Digital Water Supply KV 600
• Consumables for calibrations and installation
Features and Benefits:
• The C 2000 basic is equipped with a very convenient console to operate the unit.
• Compact, integrated modular design for convenient operation
• Automatic water handling system includes tempering, filling and emptying of calorimeter inner vessel
• Automatic oxygen filling of decomposition vessel
• Automatic decomposition vessel identification
• Automatic sample ignition
• Validation according to DIN 51900,ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711
• 1+1 year warranty after registering at www.ika.com/register
• 24 hour technical support hotline
• Manufactured in the USA
Read More
The modes have different measuring times:
isoperibol, measurement time: approx. 22 min
dynamic, measurement time: approx. 7 min
Cooling water supply via thermostat e.g. IKA KV 600 (Ident. No. 3410501) or firmly installed water connection (C 25 pressure regulating valve (Ident. No. 3197200) recommended)
Interface connections for each of the following: scale, printer, monitor and sample rack C 5020 (Ident. No. 7145000)
User-friendly software C 5040 CalWin (Ident. No. 3045000) is available for controlling the bomb calorimeter and analyzing measuring data for the determination of sample gross calorific values.
Up to eight oxygen bomb calorimeters can be controlled by a single PC, using a multi-serial plug-in card PCI 8.2 (accessory)
|
 |
|
Item: |
8801891 |
Price |
$27,163.00 |
|
|
|
|
|
|
| |
| C 2000 basic version 2 Calorimeter |
The IKA C 2000 basic bomb calorimeter is a combustion calorimeter for determining gross calorific values of liquid and solid samples. A high level of automation with extremely simple handling characterizes this instrument. In addition to the isoperibolic measurement procedure (static jacket), a dynamic (reduced-time) working method is also available. To provide the calorimeter with cooling water, it needs to be connected to the IKA thermostat KV 600, which is included in this package.
The C 2000 system consists of the following components:
• Measuring cell C 2000
• Decomposition vessel, halogen-resistant C 5012
• Digital Water Supply KV 600
• Consumables for calibrations and installation
Features and Benefits:
• The C 2000 basic is equipped with a very convenient console to operate the unit.
• Compact, integrated modular design for convenient operation
• Automatic water handling system includes tempering, filling and emptying of calorimeter inner vessel
• Automatic oxygen filling of decomposition vessel
• Automatic decomposition vessel identification
• Automatic sample ignition
• Validation according to DIN 51900,ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711
• 1+1 year warranty after registering at www.ika.com/register
• 24 hour technical support hotline
• Manufactured in the USA.
Read More
The modes have different measuring times:
isoperibol, measurement time: approx. 22 min
dynamic, measurement time: approx. 7 min
Cooling water supply via thermostat e.g. IKA KV 600 (Ident. No. 3410501) or firmly installed water connection (C 25 pressure regulating valve (Ident. No. 3197200) recommended)
Interface connections for each of the following: scale, printer, monitor and sample rack C 5020 (Ident. No. 7145000)
User-friendly software C 5040 CalWin (Ident. No. 3045000) is available for controlling the bomb calorimeter and analyzing measuring data for the determination of sample gross calorific values.
Up to eight oxygen bomb calorimeters can be controlled by a single PC, using a multi-serial plug-in card PCI 8.2 (accessory)
LIMS integration is possible
The decomposition vessel can be changed over to use combustible crucibles C 14 (Ident. No. 7224500). When using these combustion crucibles, C 5010.4 attachment for combustible crucible C14 (Ident No. 3016900) is required
|
 |
|
Item: |
8801901 |
Price |
$23,390.00 |
|
|
|
|
| |
| C 5000 control package 1/10 Calorimeter |
The IKA C 5000 control is the only bomb calorimeter in the world that offers a free selection of 3 working methods. As such, it is therefore possible to perform determinations of gross calorific values of liquid and solid samples in adiabatic (approx. 14 - 18 min), isoperibolic (approx. 22 min) and dynamic (reduced time: approx. 10 min) mode. A high level of automation in addition to an extensive range of accessories leaves this calorimeter system first in class.
The C 5000 control package 1/10 consists of the following components:
• Measuring cell C 5003
• Decomposition vessel C 5010
• Cooling system C 5001
• Consumables for calibrations and installation
Features and Benefits:
• Automatic water handling system includes tempering, filling and emptying of calorimeter inner vessel
• Automatic oxygen filling and degassing of the decomposition vessel
• Automatic decomposition vessel identification
• Validation according to DIN 51900,ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711
• 1+1 year warranty after registering at www.ika.com/register
• 24 hour technical support hotline
• Manufactured in the USA.
Read More
Interface connections for each of the following: scale, printer, monitor and sample rack C 5020 (Ident. No. 7145000)
User-friendly software C 5040 CalWin (Ident. No. 3045000) is available for controlling the bomb calorimeter and analyzing measuring data for the determination of sample gross calorific values.
LIMS integration is possible
C 5012 Halogen-resistant decomposition vessel (Ident. No. 3017000) for quantitative decomposition of halogens and sulfur can be utilized
The decomposition vessel can be changed over to use combustible crucibles C 14 (Ident. No. 7224500). When using these combustion crucibles, C 5010.4 attachment for combustible crucible C14 (Ident No. 3016900) is required
The C 5000 control can be expanded to the duo-control system with two measurement cells at any given time
|
 |
|
Item: |
8803001 |
Price |
$31,818.00 |
|
|
| |
| C 5000 control package 1/12 Calorimeter |
The IKA C 5000 control is the only bomb calorimeter in the world that offers a free selection of 3 working methods. As such, it is therefore possible to perform determinations of gross calorific values of liquid and solid samples in adiabatic (approx. 14 - 18 min), isoperibolic (approx. 22 min) and dynamic (reduced time: approx. 10 min) mode. A high level of automation in addition to an extensive range of accessories leaves this calorimeter system first in class.
The C 5000 control package 1/12 consists of the following components:
• Measuring cell C 5003
• Decomposition vessel, halogen-resistant C 5012
• Cooling system C 5001
• Consumables for calibrations and installation
Features and Benefits:
• Automatic water handling system includes tempering, filling and emptying of calorimeter inner vessel
• Automatic oxygen filling and degassing of the decomposition vessel
• Automatic decomposition vessel identification
• Validation according to DIN 51900,ISO 1928, ASTM D240, ASTM D4809, ASTM D5865, ASTM D1989, ASTM D5468, ASTM E711
• 1+1 year warranty after registering at www.ika.com/register
• 24 hour technical support hotline
• Manufactured in the USA.
Read More
Interface connections for each of the following: scale, printer, monitor and sample rack C 5020 (Ident. No. 7145000)
User-friendly software C 5040 CalWin (Ident. No. 3045000) is available for controlling the bomb calorimeter and analyzing measuring data for the determination of sample gross calorific values.
LIMS integration is possible
C 5012 Halogen-resistant decomposition vessel (Ident. No. 3017000) for quantitative decomposition of halogens and sulfur can be utilized
The decomposition vessel can be changed over to use combustible crucibles C 14 (Ident. No. 7224500). When using these combustion crucibles, C 5010.4 attachment for combustible crucible C14 (Ident No. 3016900) is required
The C 5000 control can be expanded to the duo-control system with two measurement cells at any given time
|
 |
|
Item: |
8803301 |
Price |
$39,185.00 |
|
|
| |
|